Drug factory · FDA FEI 3002942061
Janssen Ortho LLC
State Road 933 KM 0.1, Mamey Ward, Gurabo, PR, United States
Problems found, fixed voluntarily at FDA's last inspection, Mar 28, 2023.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
7 drug inspections on record since 2011: 0 with no problems, 7 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Mar 28, 2023 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Aug 28, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| May 26, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 10 |
| May 29, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Feb 22, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Feb 22, 2013 | Problems found, fixed voluntarily | Bioresearch Monitoring | — |
| Jun 13, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Mar 28, 2023 inspection
- Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Approve or reject components, products 21 CFR 211.22(a)
The quality control unit lacks the responsibility and authority to reject all components and drug product containers. - Equipment construction - reactive surfaces 21 CFR 211.65(a)
Equipment surfaces that contact components are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements.
Aug 28, 2018 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations made into any unexplained discrepancy 21 CFR 211.188(b)(12)
Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
May 26, 2017 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. - Following/documenting laboratory controls 21 CFR 211.160(a)
Established laboratory control mechanisms are not followed and documented at the time of performance. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Complete test data included in records 21 CFR 211.194(a)
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration and inspection of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
May 29, 2015 inspection
- Examinations documented 21 CFR 211.134(c)
The results of the examination of the packaged and labeled products were not documented in the batch production or control records. - Samples (various types) representative, identified properly 21 CFR 211.160(b)(1)
Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components are not representative. - Drug products - samples representative, identified properly 21 CFR 211.160(b)(3)
Samples taken of drug products for determination of conformance to written specifications are not representative.
Registered with FDA for: analysis; label; manufacture; pack.