Drug factory · FDA FEI 3003585550
Victor Welding Supply Company
123 S Peoria Ave, Tulsa, OK, United States
Problems found, fixed voluntarily at FDA's last inspection, Nov 5, 2015.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
3 drug inspections on record since 2011: 1 with no problems, 2 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Nitrogen | Makes it | Victor Welding Supply Company | 66961-120 |
| Oxygen | Makes it | Victor Welding Supply Company | 66961-100 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Nov 5, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Jun 6, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Sep 14, 2011 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Nov 5, 2015 inspection
- Procedures Written and Followed 21 CFR 211.125(f)
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not followed. - Calibration - at intervals, written program, remedial action 21 CFR 211.160(b)(4)
The calibration of gauges and recording devices is not done at suitable intervals in accordance with an established written program. - Labeling Control Records and Label Copies 21 CFR 211.188(b)(8)
The batch production and control records are deficient in that they do not include copy of labeling. - Authority lacking to review records, investigate errors 21 CFR 211.22(a)
The quality control unit lacks authority to fully investigate errors that have occurred. - GMP Training Frequency 21 CFR 211.25(a)
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them. - Unauthorized Personnel in Limited Access Areas 21 CFR 211.28(c)
Unauthorized personnel have access to enter areas of the buildings and facilities designated as limited access areas.
Jun 6, 2012 inspection
- Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Registered with FDA for: manufacture.