Drug factory · FDA FEI 3007432449
Technical Gas Products, Inc.
9 Avenue E, Hopkinton, MA, United States
Problems found, fixed voluntarily at FDA's last inspection, Apr 30, 2015.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
1 drug inspection on record since 2015: 0 with no problems, 1 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Oxygen | Repackages it | Technical Gas Products, Inc. | 65010-001, 65010-002 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Apr 30, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Apr 30, 2015 inspection
- Labeling Control Records and Label Copies 21 CFR 211.188(b)(8)
The batch production and control records are deficient in that they do not include specimen of labeling. - No written record of investigation 21 CFR 211.192
Written records are not always made of investigations into the failure of a batch or any of its components to meet specifications . - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed . - In-Process Material Area 21 CFR 211.42(c)(4)
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the storage of in-process materials. - Written procedures fail to include 21 CFR 211.67(b)
Written procedures for cleaning and maintenance fail to include maintenance and cleaning schedules .
Registered with FDA for: repack.