Drug factory · FDA FEI 1000115571
Simtra US LLC
927 South Curry Pike, Bloomington, IN, United States
Problems found, fixed voluntarily at FDA's last inspection, Sep 24, 2024.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
12 drug inspections on record since 2009: 4 with no problems, 8 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Adenosine | Makes it, tests it, packages it, labels it and sterilizes it | Hikma Pharmaceuticals USA Inc. | 0641-6113 |
| Aflibercept | Makes it, tests it, packages it and labels it | Regeneron Pharmaceuticals, Inc. | 61755-005 |
| Daratumumab | Makes it, packages it and labels it | Janssen Biotech, Inc. | 57894-502 |
| Garetosmab | Makes it and tests it | Regeneron Pharmaceuticals, Inc. | 61755-012 |
| Golimumab | Makes it and tests it | Janssen Biotech, Inc. | 57894-070, 57894-071, 57894-350 |
| Regadenoson | Makes it, tests it, packages it, labels it and sterilizes it | Baxter Healthcare Corporation | 36000-364 |
| Ustekinumab | Makes it | Janssen Biotech, Inc. | 57894-060, 57894-061, 57894-440 +1 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Sep 24, 2024 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Feb 17, 2023 | No problems found | Drug Quality Assurance | — |
| Jul 17, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Oct 24, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 2, 2014 | No problems found | Drug Quality Assurance | — |
| May 10, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Mar 12, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Sep 27, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Aug 16, 2011 | No problems found | Drug Quality Assurance | — |
| Mar 25, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Sep 23, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Oct 30, 2009 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jul 17, 2017 inspection
- Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
May 10, 2013 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Procedures To Be in Writing 21 CFR 211.80(a)
Written procedures are lacking which describe in sufficient detail the testing of drug product containers and closures. - Certificates of Testing (Containers, Closures) 21 CFR 211.84(d)(3)
Certificates of testing of containers and closures are accepted in lieu of testing without establishing the reliability of the supplier's test results through appropriate validation of the test results at appropriate intervals.
Mar 12, 2013 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. - Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy.
Mar 25, 2011 inspection
- Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Registered with FDA for: analysis; label; manufacture; pack; relabel; sterilize.