Drug factory · FDA FEI 3008425092
Sam Chun Dang Pharm Co, Ltd
71 Jeyakgongdan-2Gil; Hyangnam-eup, Hwaseong, South Korea
Serious problems, FDA action at FDA's last inspection, May 19, 2026.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
4 drug inspections on record since 2017: 0 with no problems, 2 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Brimonidine and Timolol | Makes it | Glenmark Pharmaceuticals Inc., USA | 68462-281 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| May 19, 2026 | Serious problems, FDA action | Drug Quality Assurance | 8 |
| Oct 27, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Oct 25, 2019 | Serious problems, FDA action | Drug Quality Assurance | 14 |
| Sep 8, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 7 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
May 19, 2026 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Aseptic Processing Area 21 CFR 211.42(c)(10)
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Oct 27, 2022 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
Oct 25, 2019 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Samples (various types) representative, identified properly 21 CFR 211.160(b)(1)
Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of drug product containers are not adequately identified. - Calibration - at intervals, written program, remedial action 21 CFR 211.160(b)(4)
The calibration of instruments and apparatus is not done at suitable intervals. - Microbiological testing 21 CFR 211.165(b)
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. - Batch production and Batch Control Record Requirements 21 CFR 211.188(b)
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding. - Complete test data included in records 21 CFR 211.194(a)
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are not written or followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations. - Aseptic Processing Area 21 CFR 211.42(c)(10)
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Released Drug Products Area 21 CFR 211.42(c)(8)
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the storage of drug products after release. - Backup file not maintained 21 CFR 211.68(b)
Failure to maintain a backup file of data entered into the computer or related system. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Sep 8, 2017 inspection
- Establishment of time limitations 21 CFR 211.111
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. - Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. - Valid stability test methods 21 CFR 211.166(a)(3)
The written stability program for drug products does not include reliable, meaningful and specific test methods. - Complete Test Data 21 CFR 211.194(a)(4)
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Registered with FDA for: manufacture.