Drug factory · FDA FEI 1925262
Hospira, Inc.
1776 North Centennial Drive, McPherson, KS, United States
Problems found, fixed voluntarily at FDA's last inspection, Jan 17, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
16 drug inspections on record since 2009: 6 with no problems, 8 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jan 17, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Jan 17, 2020 | Problems found, fixed voluntarily | Drug Quality Assurance | 10 |
| Aug 15, 2018 | Serious problems, FDA action | Drug Quality Assurance | — |
| Oct 27, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 8, 2016 | Serious problems, FDA action | Drug Quality Assurance | — |
| Apr 3, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Apr 23, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Aug 16, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Oct 24, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 25, 2012 | No problems found | Drug Quality Assurance | — |
| Jan 4, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 25, 2011 | No problems found | Drug Quality Assurance | — |
| May 5, 2011 | No problems found | Drug Quality Assurance | — |
| Apr 16, 2010 | No problems found | Drug Quality Assurance | — |
| Aug 27, 2009 | No problems found | Drug Quality Assurance | — |
| Apr 9, 2009 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jan 17, 2025 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Jan 17, 2020 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions. - Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - In-process conformity - examination, sample testing 21 CFR 211.110(b)
Your examination and testing of samples did not assure that the drug product and in-process material conformed to specifications. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. - Acceptance criteria for sampling & testing 21 CFR 211.165(d)
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. - Complete instructions, procedures, specifications et. al. 21 CFR 211.186(b)(9)
Master production and control records lack complete manufacturing and control instructions and precautions to be followed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Written record of investigation incomplete 21 CFR 211.192
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Exhaust systems inadequate to control air contamination 21 CFR 211.46(c)
Adequate exhaust systems or other systems to control contaminants are lacking in areas where air contamination occurs during production.
Registered with FDA for: analysis; label; manufacture; pack.