Drug factory · FDA FEI 3008461619
Eugia Pharma Specialities Limited
Unit-III, Plot No: 4, 34 to 40, 41P, 44 to 48, EPIP, TSIIC, IDA, Pashamylaram Village, Patancheru Mandal, Sangareddy, India
Serious problems, FDA action at FDA's last inspection, Feb 6, 2026.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
7 drug inspections on record since 2012: 1 with no problems, 4 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Feb 6, 2026 | Serious problems, FDA action | Drug Quality Assurance | 11 |
| Feb 2, 2024 | Serious problems, FDA action | Drug Quality Assurance | 9 |
| Dec 14, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Feb 20, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 16, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 26, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 12, 2012 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Feb 6, 2026 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Following/documenting laboratory controls 21 CFR 211.160(a)
Established laboratory control mechanisms are not followed. - Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. - Sterility/pyrogens - test methods written, followed 21 CFR 211.167(a)
Test procedures relative to appropriate laboratory testing for pyrogens are not followed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Second person sign off 21 CFR 211.194(a)(8)
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in the particular operations they perform as part of their function. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Equipment to control conditions 21 CFR 211.42(c)(10)(vi)
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Feb 2, 2024 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Changes to Procedures Not Reviewed, Approved 21 CFR 211.100(a)
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Prepared for each batch, include complete information 21 CFR 211.188
Batch production and control records do not include complete information relating to the production and control of each batch. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Complete test data included in records 21 CFR 211.194(a)
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Dec 14, 2018 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Protective Apparel Not Worn 21 CFR 211.28(a)
Protective apparel is not worn as necessary to protect drug products from contamination.
Registered with FDA for: analysis; manufacture; pack.