Problems found, fixed voluntarily at FDA's last inspection, Jun 12, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
14 drug inspections on record since 2008: 6 with no problems, 8 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jun 12, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Dec 7, 2023 | No problems found | Bioresearch Monitoring | — |
| Oct 23, 2023 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Feb 1, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Nov 6, 2018 | Problems found, fixed voluntarily | Bioresearch Monitoring | 1 |
| Apr 21, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Jun 4, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Dec 23, 2013 | No problems found | Drug Quality Assurance | — |
| Nov 1, 2012 | No problems found | Drug Quality Assurance | — |
| Oct 13, 2011 | Problems found, fixed voluntarily | Unapproved and Misbranded Drugs | — |
| Oct 13, 2011 | No problems found | Drug Quality Assurance | — |
| Nov 16, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Mar 5, 2010 | No problems found | Drug Quality Assurance | — |
| Nov 14, 2008 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jun 12, 2026 inspection
- Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. - Mix-up 21 CFR 314.81(b)(1)(i)
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning an incident that caused a drug product or its labeling to be mistaken for and applied to another article.
Oct 23, 2023 inspection
- Cleaning SOPs/instructions 21 CFR 211.67(b)(3)
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Feb 1, 2019 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - In-process conformity - examination, sample testing 21 CFR 211.110(b)
Your examination and testing of samples did not assure that the drug product and in-process material conformed to specifications. - Storage under appropriate conditions 21 CFR 211.142(b)
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance. - Procedures To Be in Writing 21 CFR 211.80(a)
Written procedures are lacking which describe in sufficient detail the identification and handling of components.
Nov 6, 2018 inspection
- Failure to develop written procedures 21 CFR 314.80(b)
Written procedures have not been developed for the of post marketing adverse drug experiences.