Drug factory · FDA FEI 1025114
Baxter Healthcare Corporation
65 Pitts Station Rd, Marion, NC, United States
Serious problems, FDA action at FDA's last inspection, Feb 9, 2024.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
9 drug inspections on record since 2009: 2 with no problems, 4 with problems fixed voluntarily, 3 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Feb 9, 2024 | Serious problems, FDA action | Drug Quality Assurance | 7 |
| Jul 1, 2021 | No problems found | Drug Quality Assurance | — |
| Nov 17, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Feb 26, 2016 | Serious problems, FDA action | Drug Quality Assurance | 5 |
| Jan 24, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Nov 16, 2012 | Serious problems, FDA action | Drug Quality Assurance | 10 |
| Aug 31, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Aug 27, 2010 | No problems found | Drug Quality Assurance | — |
| Aug 19, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Feb 9, 2024 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Control procedures fail to include the following 21 CFR 211.110(a)
Control procedures fail to include adequacy of mixing to assure uniformity and homogeneity. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Nov 17, 2017 inspection
- Batch production and Batch Control Record Requirements 21 CFR 211.188(b)
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Training , Education , Experience overall 21 CFR 211.25(a)
Employees engaged in the manufacture, processing and packing of a drug product lack the training required to perform their assigned functions. - Buildings not maintained in good state of repair 21 CFR 211.58
Buildings used in the manufacturing of a drug product are not maintained in a good state of repair.
Feb 26, 2016 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Training , Education , Experience overall 21 CFR 211.25(a)
Employees engaged in the manufacture , processing and packing of a drug product lack the training required to perform their assigned functions. - Sanitation--buildings not clean, free of infestation 21 CFR 211.56(a)
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Jan 24, 2014 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Cleaning/maintenance records not kept 21 CFR 211.67(c)
Records are not kept for the cleaning of equipment.
Registered with FDA for: analysis; api manufacture; label; manufacture; pack; sterilize.