Drug factory · FDA FEI 2250062
Airgas Usa, LLC
1910 Old Cuthbert Rd, Cherry Hill, NJ, United States
Problems found, fixed voluntarily at FDA's last inspection, Sep 28, 2018.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
2 drug inspections on record since 2013: 1 with no problems, 1 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Helium | Makes it | Airgas USA, LLC | 11054-004 |
| Helium and Oxygen | Makes it | Airgas USA, LLC | 11054-032, 11054-041, 11054-042 |
| Nitrogen | Makes it | Airgas USA, LLC | 11054-006 |
| Oxygen | Makes it | Airgas USA, LLC | 11054-010 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Sep 28, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 9 |
| May 21, 2013 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Sep 28, 2018 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Distribution Recall System 21 CFR 211.150(b)
The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary. - Acceptance of drug products 21 CFR 211.160(b)(3)
Determinations of conformance to appropriate written specifications for acceptance are not made for drug products. - Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. - Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product. - Batch production and Batch Control Record Requirements 21 CFR 211.188(b)
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in the particular operations they perform as part of their function and written procedures required by current good manufacturing practice regulations. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Registered with FDA for: manufacture.