Problems found, fixed voluntarily at FDA's last inspection, Nov 15, 2024.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
6 drug inspections on record since 2009: 1 with no problems, 3 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Temsirolimus | Tests it and labels it | Wyeth Pharmaceuticals LLC, a subsidiary of Pfizer Inc. | 0008-1179 |
| Tigecycline | Makes it, tests it, packages it and labels it | Wyeth Pharmaceuticals LLC, a subsidiary of Pfizer Inc. | 0008-4990, 0008-4994 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Nov 15, 2024 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jan 21, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Apr 20, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Nov 14, 2014 | Serious problems, FDA action | Drug Quality Assurance | 13 |
| Jul 20, 2012 | Serious problems, FDA action | Drug Quality Assurance | — |
| Dec 4, 2009 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Apr 20, 2017 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. - Microbiological testing 21 CFR 211.165(b)
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. - Complete test data included in records 21 CFR 211.194(a)
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Nov 14, 2014 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Following/documenting laboratory controls 21 CFR 211.160(a)
Established test procedures and laboratory control mechanisms are not followed. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - GMP Training Frequency 21 CFR 211.25(a)
GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them. - Defined areas of adequate size for operations 21 CFR 211.42(c)
The control systems necessary to prevent contamination or mix-ups are deficient. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Cleaning System 21 CFR 211.42(c)(10)(v)
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. - Sanitation--buildings not clean, free of infestation 21 CFR 211.56(a)
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. - Contamination, chemical or physical change, deterioration 21 CFR 314.81(b)(1)(ii)
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Registered with FDA for: analysis; label; manufacture; pack.