Drug factory · FDA FEI 3010062344
Wes Pharma Inc
1221 TECH COURT, Westminster, MD, United States
Problems found, fixed voluntarily at FDA's last inspection, Nov 20, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
7 drug inspections on record since 2018: 3 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Nov 20, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Nov 21, 2023 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Feb 18, 2022 | No problems found | Drug Quality Assurance | — |
| Apr 28, 2021 | No problems found | Bioresearch Monitoring | — |
| Dec 20, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Apr 19, 2019 | No problems found | Bioresearch Monitoring | — |
| Dec 13, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Nov 20, 2025 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Second person sign off 21 CFR 211.194(a)(8)
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy. - Authority lacking to review records, investigate errors 21 CFR 211.22(a)
The quality control unit lacks authority to fully investigate errors that have occurred. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained at appropriate intervals to prevent that would alter the safety, identity, strength, quality or purity of the drug product.
Nov 21, 2023 inspection
- Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Registered with FDA for: analysis; label; manufacture; pack.