Drug factory · FDA FEI 2627208
Viatris Pharmaceuticals LLC
Road #2 Km 58.2, Barceloneta, PR, United States
No problems found at FDA's last inspection, Jun 13, 2025.
No Action Indicated: inspectors found no objectionable conditions.
8 drug inspections on record since 2010: 2 with no problems, 5 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Amlodipine and Atorvastatin | Makes the active ingredient and tests it | Pfizer Laboratories Div Pfizer Inc, Viatris Specialty LLC | 0069-2150, 0069-2160, 0069-2170 +21 |
| Nifedipine | Makes it and tests it | Pfizer Laboratories Div Pfizer Inc | 0069-2650, 0069-2660 |
| Tofacitinib | Makes it and tests it | Pfizer Laboratories Div Pfizer Inc, U.S. Pharmaceuticals | 0069-0501, 0069-0502, 63539-501 +1 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jun 13, 2025 | No problems found | Drug Quality Assurance | — |
| Dec 20, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 28, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Dec 8, 2016 | No problems found | Drug Quality Assurance | — |
| Jul 2, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Aug 20, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 16 |
| Sep 23, 2011 | Serious problems, FDA action | Drug Quality Assurance | 9 |
| Feb 8, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Mar 28, 2018 inspection
- Following/documenting laboratory controls 21 CFR 211.160(a)
Established standards are not followed. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Complete Test Data 21 CFR 211.194(a)(4)
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. - Handling and Storage to Prevent Contamination 21 CFR 211.80(b)
There was a failure to handle and store components at all times in a manner to prevent contamination.
Jul 2, 2015 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Following/documenting laboratory controls 21 CFR 211.160(a)
Established laboratory control mechanisms are not followed. - Establishment of calibration procedures 21 CFR 211.160(b)(4)
Procedures describing the calibration of instruments, apparatus, gauges and recording devices are deficiently written or followed. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
Aug 20, 2013 inspection
- Following/documenting laboratory controls 21 CFR 211.160(a)
Established laboratory control mechanisms are not followed and documented at the time of performance. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. - Valid stability test methods 21 CFR 211.166(a)(3)
The written stability program for drug products does not include reliable, meaningful, and specific test methods. - Reserve samples identified, representative, stored 21 CFR 211.170(b)
Reserve drug product samples are not appropriately identified. - Complete instructions, procedures, specifications et. al. 21 CFR 211.186(b)(9)
Master production and control records lack complete manufacturing and control instructions and sampling and testing procedures. - Written record of investigation incomplete 21 CFR 211.192
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. - Complete test data included in records 21 CFR 211.194(a)
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards. - Sample identification and other information 21 CFR 211.194(a)(1)
Laboratory records do not include the quantity of the sample. - Data secured in course of each test 21 CFR 211.194(a)(4)
Laboratory records do not include a complete record of all data secured in the course of each test, including all graphs from laboratory instrumentation, properly identified to show the lot tested and drug product tested. - Laboratory equipment calibration records 21 CFR 211.194(d)
Laboratory records do not include complete records of the periodic calibration of laboratory instruments. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Written procedures fail to include 21 CFR 211.67(b)
Written procedures for cleaning and maintenance fail to include assignment of responsibility and description in sufficient detail of methods, equipment and materials used. - Cleaning/maintenance records not kept 21 CFR 211.67(c)
Records are not kept for the maintenance and inspection of equipment. - input/output verification 21 CFR 211.68(b)
Input to and output from the computer, related systems of formulas, and records or data are not checked for accuracy. - Failure to meet specifications 21 CFR 314.81(b)(1)(ii)
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning a failure of one or more distributed batches of a drug to meet the specifications established for it in the application.
Sep 23, 2011 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Procedures for non-sterile drug products 21 CFR 211.113(a)
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not followed. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity. - Acceptance of in-process materials 21 CFR 211.160(b)(2)
Determinations of conformance to appropriate written specifications for acceptance are not made for in-process materials. - Complete instructions, procedures, specifications et. al. 21 CFR 211.186(b)(9)
Master production and control records lack complete manufacturing and control instructions and special notations. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Registered with FDA for: analysis; manufacture.