Drug factory · FDA FEI 1010370
USpharma Ltd
13900 N.W. 57 Court, Miami Lake, FL, United States
Problems found, fixed voluntarily at FDA's last inspection, Sep 3, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
7 drug inspections on record since 2010: 4 with no problems, 3 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Nitroglycerin | Makes it | Dr. Reddy's Laboratories Inc., Ingenus Pharmaceuticals, LLC | 43598-893, 43598-894, 43598-895 +7 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Sep 3, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Feb 16, 2023 | No problems found | Drug Quality Assurance | — |
| Jun 23, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Feb 3, 2015 | No problems found | Drug Quality Assurance | — |
| Apr 2, 2012 | No problems found | Postmarket Surv. and Epidemiology | — |
| Apr 2, 2012 | No problems found | Drug Quality Assurance | — |
| May 11, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Sep 3, 2026 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Jun 23, 2022 inspection
- Test methods 21 CFR 211.165(e)
The sensitivity of test methods have not been established. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Complete Test Data 21 CFR 211.194(a)(4)
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
May 11, 2010 inspection
- Representative Samples 21 CFR 211.84(b)
Representative samples are not taken of each shipment of each lot of components for testing or examination. - Establish reliability of supplier's C of A 21 CFR 211.84(d)(2)
Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
Registered with FDA for: analysis; manufacture; pack.