Drug factory · FDA FEI 3009211584
University of California, Los Angeles
780 WESTWOOD PLZ, Los Angeles, CA, United States
Problems found, fixed voluntarily at FDA's last inspection, Jul 31, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
4 drug inspections on record since 2012: 0 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Gallium Ga-68 Gozetotide | Makes it | UCLA Biomedical Cyclotron | 76394-2642 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jul 31, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Jul 31, 2020 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 2, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Aug 24, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jul 31, 2025 inspection
- Specifications and processes 21 CFR 212.20(c)
You did not approve or reject, before implementation, processes or procedures to ensure that they maintain the identity, strength, quality, and purity of a PET drug. - Supplies adequately controlled 21 CFR 212.60(d)
Your quality of supplies used in your testing procedures are not adequately controlled. - Conform to specs prior to release 21 CFR 212.70(c)
You did not conduct an appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications before final release.
Jun 2, 2016 inspection
- Determination need for investigation 21 CFR 212.20(d)
When errors occurred or a production batch failed to meet specifications, you did not determine the need for an investigation, conduct an investigation and take appropriate corrective actions when necessary. - Written QA procedures established, followed 21 CFR 212.20(e)
You did not establish and follow written quality assurance procedures. - Contamination, mix-ups and deterioration 21 CFR 212.40(d)
You did not handle and store components, containers and closures in a manner that prevents contamination and deterioration and ensures that they are and remain suitable for their intended use. - Complete instructions, procedures, specs 21 CFR 212.50(b)(7)
Your master production and control records did not contain complete production and control instructions, complete sampling and testing procedures and complete specifications. - Results of investigations 21 CFR 212.50(c)(11)
Your batch production and control records did not include the results of any investigations conducted. - Complete record of all laboratory test data 21 CFR 212.60(g)(3)
Laboratory records did not contain a complete record of all data obtained in the course of each test.
Registered with FDA for: positron emission tomography drug production.