Drug factory · FDA FEI 3005947301
UCSF Radiopharmaceutical Facility
185 Berry Street Suite 350, San Francisco, CA, United States
Serious problems, FDA action at FDA's last inspection, Jul 24, 2025.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
3 drug inspections on record since 2015: 0 with no problems, 2 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Ammonia N-13 | Makes it | UCSF Radiopharmaceutical Facility | 24275-0385 |
| Fludeoxyglucose F-18 | Makes it | UCSF Radiopharmaceutical Facility | 24275-0185 |
| Gallium Ga-68 Gozetotide | Makes it | UCSF Radiopharmaceutical Facility | 24275-0525 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jul 24, 2025 | Serious problems, FDA action | Drug Quality Assurance | 4 |
| Jul 24, 2020 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Nov 5, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jul 24, 2025 inspection
- Written QA procedures established, followed 21 CFR 212.20(e)
You did not follow written quality assurance procedures. - Adequate controls (general) 21 CFR 212.50
Your firm lacks adequate production and process controls to ensure the consistent production of a PET drug that meets the applicable standards of identity, strength, quality and purity. - Written control procedures 21 CFR 212.50(a)
You did not have written production and process control procedures to ensure that all key process parameters are controlled. - Conform to specs prior to release 21 CFR 212.70(c)
You did not conduct an appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications before final release.
Nov 5, 2015 inspection
- Lab written procedures 21 CFR 212.60(f)
Laboratory written procedures are not established to ensure that the lab equipment is routinely calibrated and maintained.
Registered with FDA for: positron emission tomography drug production.