Drug factory · FDA FEI 3004554612
Strides Pharma Science Limited
No 36/7, Suragajakkanahalli, Indlavadi Cross, Anekal Taluk, Bengaluru, India
Problems found, fixed voluntarily at FDA's last inspection, May 20, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
11 drug inspections on record since 2011: 4 with no problems, 7 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| May 20, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Dec 9, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 5, 2020 | No problems found | Drug Quality Assurance | — |
| Jan 17, 2020 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| May 24, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Nov 2, 2018 | No problems found | Drug Quality Assurance | — |
| May 26, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Feb 19, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Aug 26, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Dec 20, 2013 | No problems found | Drug Quality Assurance | — |
| Jul 22, 2011 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jan 17, 2020 inspection
- Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product.
May 24, 2019 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. - Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product. - Written record of investigation incomplete 21 CFR 211.192
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
Aug 26, 2014 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not followed for evaluations done at least annually and including provisions for a review of returned or salvaged drug products and investigations conducted for each drug product. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Complaint Investigation/Follow-Up Findings 21 CFR 211.198(b)(2)
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Registered with FDA for: analysis; manufacture; pack.