Drug factory · FDA FEI 3008585015
Steri-Pharma, LLC
429 S West Street, Syracuse, NY, United States
Matched to FDA's records by company name, because this plant's registration on the label has expired.
Serious problems, FDA action at FDA's last inspection, Aug 8, 2025.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
5 drug inspections on record since 2012: 1 with no problems, 3 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Cefuroxime | Makes it | WG Critical Care, LLC. | 44567-712 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Aug 8, 2025 | Serious problems, FDA action | Drug Quality Assurance | 3 |
| Oct 4, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Mar 24, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Oct 10, 2014 | No problems found | Drug Quality Assurance | — |
| Sep 20, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Aug 8, 2025 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Oct 4, 2022 inspection
- Following/documenting laboratory controls 21 CFR 211.160(a)
Established specifications, test procedures and laboratory control mechanisms are not followed and documented at the time of performance. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Mar 24, 2017 inspection
- Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Sep 20, 2012 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions.
Registered with FDA for: analysis; manufacture; pack.