Drug factory · FDA FEI 1317295
SpecGx LLC
172 Railroad Avenue P.O. Box P, Hobart, NY, United States
No problems found at FDA's last inspection, Mar 13, 2020.
No Action Indicated: inspectors found no objectionable conditions.
6 drug inspections on record since 2010: 2 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Mar 13, 2020 | No problems found | Drug Quality Assurance | — |
| Apr 6, 2018 | No problems found | Drug Quality Assurance | — |
| Jan 29, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Aug 30, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Apr 20, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Jan 27, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jan 29, 2016 inspection
- Storage under appropriate conditions 21 CFR 211.142(b)
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected. - Accurate reproduction included 21 CFR 211.188(a)
Batch production and control records for each batch of drug product produced do not include an accurate reproduction of the appropriate master production or control record which was checked for accuracy, dated and signed.
Aug 30, 2013 inspection
- Approval and review of procedures 21 CFR 211.100(a)
Written procedures are not drafted, reviewed and approved by the appropriate organizational units. - SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions. - Establishment of time limitations 21 CFR 211.111
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Apr 20, 2012 inspection
- Establishment of time limitations 21 CFR 211.111
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Sanitation--buildings not clean, free of infestation 21 CFR 211.56(a)
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions that would alter the safety, identity, strength, quality or purity of the drug product. - Contamination, chemical or physical change, deterioration 21 CFR 314.81(b)(1)(ii)
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Jan 27, 2010 inspection
- Written warehousing procedures established/followed 21 CFR 211.142
Procedures describing the warehousing of drug products are not followed. - Clothing appropriate for duties performed 21 CFR 211.28(a)
Clothing of personnel engaged in the processing and packing of drug products is not appropriate for the duties they perform. - Buildings not maintained in good state of repair 21 CFR 211.58
Buildings used in the manufacturing, processing, packing, and holding of a drug product are not maintained in a good state of repair. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Registered with FDA for: analysis; distribute; manufacture; pack; relabel; repack.