Drug factory · FDA FEI 3006246010
SOFIE Co. dba SOFIE
5900b Obata Way, Gilroy, CA, United States
Problems found, fixed voluntarily at FDA's last inspection, Aug 7, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
4 drug inspections on record since 2014: 0 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Florbetaben F-18 | Makes it | Lantheus Biosciences Ltd., a Lantheus company | 54828-001 |
| Fludeoxyglucose F-18 | Makes it | SOFIE Co. dba SOFIE | 49609-101 |
| Fluoride Ion F-18 | Makes it | SOFIE Co. dba SOFIE | 49609-102 |
| Flurpiridaz F-18 | Makes it | GE Healthcare Inc. | 0407-8787 |
| Piflufolastat F-18 | Makes it | Progenics Pharmaceuticals, Inc. | 71258-022 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Aug 7, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Feb 5, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Aug 4, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Feb 14, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Aug 7, 2025 inspection
- Personnel not qualified 21 CFR 212.10
You lack personnel with the necessary training to perform their assigned functions. - Equipment procedures 21 CFR 212.30(b)
You did not implement procedures to ensure that all equipment is cleaned and suitable for its intended purposes that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. - Data and documentation review 21 CFR 212.70(d)(2)
You did not establish procedures to ensure that each batch or sub-batch of a PET drug product was not given final release until associated laboratory data and documentation were reviewed and PET drug products were demonstrated to meet specifications.
Feb 5, 2019 inspection
- Personnel not qualified 21 CFR 212.10
You lack personnel with the necessary training to perform their assigned functions. - Orderly handling, prevention of mix-ups, prevention of contamination 21 CFR 212.30(a)
Your facilities are not adequate to ensure the prevention of contamination of equipment or product by substances, personnel, or environmental conditions that could reasonably be expected to have an adverse effect on product quality. - Initials, signature, date 21 CFR 212.60(g)(5)
Laboratory test records did not contain the initials or signature of the person performing the test. - Final dated signature 21 CFR 212.70(d)(3)
You did not follow procedures to ensure that each batch or sub-batch of a PET drug was not given final release until a designated qualified individual authorized the final release by dated signature.
Aug 4, 2016 inspection
- Investigation of nonconforming product 21 CFR 212.71(b)
You did not completely document the investigation of a PET drug product that did not meet specifications.
Registered with FDA for: positron emission tomography drug production.