Drug factory · FDA FEI 3011506656
Sina Health Inc
10769 N. Frank Lloyd wright Blvd. Suite A-110, Scottsdale, AZ, United States
Problems found, fixed voluntarily at FDA's last inspection, Jan 13, 2023.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
2 drug inspections on record since 2017: 1 with no problems, 1 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Ammonia | Repackages it | Sina Health Inc | 70385-2003 |
| Diphenhydramine | Repackages it | Sina Health Inc | 70385-2007 |
| Epinephrine | Repackages it | Sina Health Inc | 70385-2008, 70385-2009, 70385-2017 +5 |
| Flumazenil | Repackages it | Sina Health Inc | 70385-2002, 70385-2021 |
| Methylprednisolone | Repackages it | Sina Health Inc | 70385-2016 |
| Naloxone | Repackages it | Sina Health Inc | 70385-2013, 70385-2033 |
| Nitroglycerin | Repackages it | Sina Health Inc | 70385-2014, 70385-2018 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jan 13, 2023 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Apr 25, 2017 | No problems found | Drug Quality Assurance | 7 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jan 13, 2023 inspection
- Approval and review of procedures 21 CFR 211.100(a)
Written procedures are not reviewed and approved by the quality control unit. - Examination of issued labels 21 CFR 211.125(b)
Labeling materials issued for a batch were not carefully examined for identity and conformity to the labeling specified in the master or batch production records. - Review of representative number of batches 21 CFR 211.180(e)(1)
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Apr 25, 2017 inspection
- Changes to Procedures Not Reviewed, Approved 21 CFR 211.100(a)
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit. - Procedures Written and Followed 21 CFR 211.125(f)
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not followed. - Storage under appropriate conditions 21 CFR 211.142(b)
Drug products are not stored under appropriate conditions of light so that their identity, strength, quality, and purity are not affected. - Review of representative number of batches 21 CFR 211.180(e)(1)
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance.
Registered with FDA for: relabel; repack.