Drug factory · FDA FEI 3002806419
Simtra Deutschland GmbH
Kantstrasse 2, Halle/Westfalen, Germany
Serious problems, FDA action at FDA's last inspection, Sep 26, 2025.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
11 drug inspections on record since 2010: 6 with no problems, 4 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| 2-Mercaptoethanesulfonic Acid | Makes it, tests it, packages it, labels it and sterilizes it | Bamboo US Bidco LCC | 83703-559 |
| 4-Hydroxycyclophosphamide | Makes it, tests it, packages it, labels it and sterilizes it | BluePoint Laboratories. | 68001-442, 68001-443, 68001-444 |
| Cytarabine and Daunorubicin | Makes it, tests it and packages it | Jazz Pharmaceuticals, Inc. | 68727-745 |
| Fosnetupitant and Palonosetron | Makes it and packages it | Helsinn Therapeutics (U.S.), Inc. | 69639-105, 69639-106 |
| Lurbinectedin | Makes it, tests it, packages it and labels it | Jazz Pharmaceuticals, Inc. | 68727-712 |
| Mecasermin | Makes it and tests it | Eton Pharmaceuticals, Inc., Ipsen Biopharmaceuticals, Inc. | 71863-216, 15054-1040 |
| Melphalan | Makes it | Acrotech Biopharma Inc | 72893-001 |
| Pralatrexate | Makes it | Acrotech Biopharma Inc, Fresenius Kabi USA, LLC | 72893-003, 72893-005, 65219-550 +1 |
| Trabectedin | Makes it | Janssen Products LP | 59676-610 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Sep 26, 2025 | Serious problems, FDA action | Drug Quality Assurance | 12 |
| May 3, 2023 | No problems found | Drug Quality Assurance | — |
| Jan 29, 2020 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 3, 2019 | No problems found | Drug Quality Assurance | — |
| Jun 14, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 27, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 18, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 7 |
| Jul 1, 2014 | No problems found | Drug Quality Assurance | — |
| Jul 20, 2013 | No problems found | Drug Quality Assurance | — |
| Aug 26, 2011 | No problems found | Drug Quality Assurance | — |
| Jul 22, 2010 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Sep 26, 2025 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that in-process materials conform to appropriate standards of identity, strength, quality and purity. - Written procedures followed 21 CFR 211.186(a)
Procedures for the preparation of master production and control records are not followed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Authority lacking to review records, investigate errors 21 CFR 211.22(a)
The quality control unit lacks authority to review production records to assure that no errors have occurred. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Cleaning System 21 CFR 211.42(c)(10)(v)
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. - Sanitation--buildings not clean, free of infestation 21 CFR 211.56(a)
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Mar 18, 2016 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. - Written record of investigation incomplete 21 CFR 211.192
Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up. - Habits of good sanitation & health 21 CFR 211.28(b)
Production personnel were not practicing good sanitation and health habits. - Product flow through building is inadequate 21 CFR 211.42(b)
The flow of drug product containers though the building is not designed to prevent contamination. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Equipment for Environmental Control 21 CFR 211.46(b)
Equipment for adequate control over air pressure and micro-organisms is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Registered with FDA for: analysis; api manufacture; label; manufacture; pack; particle size reduction; sterilize.