Drug factory · FDA FEI 3002323490
Quality Chemical Laboratories
3400 Enterprise Drive, Wilmington, NC, United States
Problems found, fixed voluntarily at FDA's last inspection, Nov 20, 2024.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
5 drug inspections on record since 2010: 1 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Amifampridine | Tests it | Catalyst Pharmaceuticals, Inc. | 69616-211 |
| Eflornithine | Tests it | Uswm, LLC | 78670-150 |
| Ensifentrine | Tests it | Merck Sharp & Dohme LLC | 83034-003 |
| Irinotecan | Tests it | Ipsen Biopharmaceuticals, Inc. | 15054-0043 |
| Methadone | Tests it | Breckenridge Pharmaceutical, Inc. | 51991-002 |
| Naloxone | Tests it | Uswm, LLC | 78670-140 |
| Oxcarbazepine | Tests it | Ajanta Pharma USA Inc. | 27241-304, 27241-305, 27241-306 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Nov 20, 2024 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Jul 27, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Sep 26, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Aug 24, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Apr 1, 2010 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Nov 20, 2024 inspection
- Written record of investigation incomplete 21 CFR 211.192
Written records of investigations into the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Jul 27, 2017 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not documented at the time of performance. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Sep 26, 2013 inspection
- Following/documenting laboratory controls 21 CFR 211.160(a)
Established test procedures are not followed. - Lab controls established, including changes 21 CFR 211.160(a)
The establishment of test procedures including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit. - Test methods 21 CFR 211.165(e)
The accuracy and reproducibility of test methods have not been established.
Aug 24, 2010 inspection
- Following/documenting laboratory controls 21 CFR 211.160(a)
Established test procedures are not followed. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented. - Laboratory equipment calibration records 21 CFR 211.194(d)
Laboratory records do not include complete records of the periodic calibration of laboratory instruments.
Registered with FDA for: analysis; api manufacture; manufacture; pack.