Drug factory · FDA FEI 3004680543
Przedsiebiorstwo Farmaceutyczne Jelfa S.A.
ul. Wincentego Pola 21, Jelenia Gora, Poland
Problems found, fixed voluntarily at FDA's last inspection, Mar 21, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
7 drug inspections on record since 2010: 2 with no problems, 4 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Methylergonovine | Makes it | Breckenridge Pharmaceutical, Inc., Pharmacist Pharmaceutical, LLC | 51991-144, 63704-004 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Mar 21, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Nov 25, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 13, 2018 | No problems found | Drug Quality Assurance | — |
| Sep 22, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 30, 2014 | No problems found | Drug Quality Assurance | — |
| May 15, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 10 |
| Oct 22, 2010 | Serious problems, FDA action | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
May 15, 2012 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. - Written program not followed 21 CFR 211.166(a)
The written stability testing program is not followed. - Laboratory Test Method Verification 21 CFR 211.194(a)(2)
Verification of the suitability of the testing methods is deficient in that they are not performed under actual conditions of use and documented on the laboratory records. - Complete Test Data 21 CFR 211.194(a)(4)
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing. - Calculations performed are in the records 21 CFR 211.194(a)(5)
Laboratory records do not include a record of all calculations performed in connection with the test. - Test method modification records not maintained 21 CFR 211.194(b)
Complete records are not maintained of any modification of an established method employed in testing. - Adequate lab facilities not available 21 CFR 211.22(b)
Adequate lab facilities for testing and approval or rejection of components and drug products are not available to the quality control unit. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. - Written procedures fail to include 21 CFR 211.67(b)
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used.
Registered with FDA for: manufacture.