Drug factory · FDA FEI 2938360
PharmPak, Inc.
1221 Andersen Drive Suite B, San Rafael, CA, United States
Problems found, fixed voluntarily at FDA's last inspection, Dec 9, 2021.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
4 drug inspections on record since 2010: 0 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Acetaminophen and Codeine | Repackages it and relabels it | PharmPak, Inc. | 54348-015 |
| Acetaminophen and Hydrocodone | Repackages it and relabels it | PharmPak, Inc. | 54348-066 |
| Prednisone | Repackages it | PharmPak, Inc. | 54348-506 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Dec 9, 2021 | Problems found, fixed voluntarily | Drug Quality Assurance | 10 |
| Mar 17, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 23, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Jun 18, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Dec 9, 2021 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. - Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented. - Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Air Supply 21 CFR 211.42(c)(10)(iii)
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. - Penicillin air handling systems not kept separate 21 CFR 211.46(d)
Air-handling systems for the manufacture, processing and packing of penicillin are not completely separate from those for other drug products for human use. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. - Reports of Analysis (Components) 21 CFR 211.84(d)(2)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
May 23, 2012 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Adequate lighting not provided 21 CFR 211.44
Adequate lighting is not provided in all areas. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Jun 18, 2010 inspection
- Penicillin processing area not kept separate 21 CFR 211.42(d)
The operations relating to the packing of penicillin are not performed in facilities separate from those used for other drug products for human use.
Registered with FDA for: relabel; repack.