Drug factory · FDA FEI 3009288779
Pharmalogic Puerto Rico, Inc.
150 Calle Federico Costa, San Juan, PR, United States
Problems found, fixed voluntarily at FDA's last inspection, Aug 21, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
4 drug inspections on record since 2013: 1 with no problems, 3 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Florbetaben F-18 | Makes it | Lantheus Biosciences Ltd., a Lantheus company | 54828-001 |
| Fludeoxyglucose F-18 | Makes it | Precision Nuclear LLC | 52768-001 |
| Piflufolastat F-18 | Makes it | Progenics Pharmaceuticals, Inc. | 71258-022 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Aug 21, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Jan 19, 2018 | No problems found | Drug Quality Assurance | — |
| Jul 22, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Dec 27, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Aug 21, 2026 inspection
- Determination need for investigation 21 CFR 212.20(d)
When errors occurred or a production batch or any component of the batch, failed to meet specifications, you did not determine the need for an investigation, conduct an investigation and take appropriate corrective actions when necessary. - Equipment procedures 21 CFR 212.30(b)
You did not implement procedures to ensure that all equipment is properly installed, maintained, and capable of repeatedly producing valid results that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. - Use of reliable suppliers 21 CFR 212.40(c)
You did not use a reliable supplier as a source of each lot of component and container. - Written control procedures 21 CFR 212.50(a)
You did not have written production and process control procedures to ensure and document that all key process parameters are controlled. - Supplies adequately controlled 21 CFR 212.60(d)
Your identity, purity and quality of supplies used in your testing procedures are not adequately controlled.
Jul 22, 2016 inspection
- Correct malfunction, re-do test 21 CFR 212.70(f)(1)(iv)
You approved a conditional final release of a PET drug product batch due to analytical equipment malfunction, but you did not document that reasonable efforts had been made to prevent recurrence of the malfunction.
Registered with FDA for: positron emission tomography drug production.