Drug factory · FDA FEI 1000222037
Noven Pharmaceuticals, Inc.
11960 SW 144 Street, Miami, FL, United States
Problems found, fixed voluntarily at FDA's last inspection, Aug 24, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
11 drug inspections on record since 2009: 5 with no problems, 4 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Dextroamphetamine | Makes it, tests it, packages it and labels it | Noven Therapeutics, LLC | 68968-0205, 68968-0210, 68968-0215 +1 |
| Estradiol | Makes it | Noven Therapeutics, LLC | 68968-6610, 68968-6625, 68968-6637 +2 |
| Estradiol and Norethindrone | Makes it and tests it | Noven Therapeutics, LLC | 68968-0514, 68968-0525 |
| Methylphenidate | Makes it and tests it | Noven Therapeutics, LLC, Padagis US LLC | 68968-5552, 68968-5553, 68968-5554 +5 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Aug 24, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Feb 13, 2026 | No problems found | Bioresearch Monitoring | — |
| Nov 17, 2021 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jan 26, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jul 10, 2015 | Serious problems, FDA action | Drug Quality Assurance | — |
| Sep 24, 2012 | No problems found | Drug Quality Assurance | — |
| Jun 4, 2012 | No problems found | Bioresearch Monitoring | — |
| May 6, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 12 |
| May 6, 2010 | No problems found | Bioresearch Monitoring | 12 |
| Feb 6, 2009 | Serious problems, FDA action | Drug Quality Assurance | 18 |
| Feb 6, 2009 | No problems found | Bioresearch Monitoring | 18 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Aug 24, 2026 inspection
- Second person sign off 21 CFR 211.194(a)(8)
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness. - Backup file not maintained 21 CFR 211.68(b)
Failure to maintain a backup file of data entered into the computer or related system. - input/output verification 21 CFR 211.68(b)
Input to and output from records or data are not checked for accuracy. - Identity Testing of Each Component 21 CFR 211.84(d)(1)
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
May 6, 2010 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Written in-process control procedures 21 CFR 211.110(a)
Written procedures are not established and followed that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch. - Written in-process control procedures 21 CFR 211.110(a)
Written procedures are not established and followed that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance. - Procedures To Be in Writing 21 CFR 211.80(a)
Written procedures are lacking which describe in sufficient detail the handling, sampling, and testing of components. - Procedures To Be in Writing 21 CFR 211.80(a)
Written procedures are lacking which describe in sufficient detail the handling, sampling, and testing of components.
Feb 6, 2009 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity. - Samples (various types) representative, identified properly 21 CFR 211.160(b)(1)
Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components are not representative. - Samples (various types) representative, identified properly 21 CFR 211.160(b)(1)
Samples taken to determine conformance to appropriate written specifications for the acceptance of each lot within each shipment of components are not representative. - Acceptance criteria for sampling & testing 21 CFR 211.165(d)
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. - Acceptance criteria for sampling & testing 21 CFR 211.165(d)
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification and appropriate statistical quality control criteria as a condition for their approval and release. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing. - Reports of Analysis (Components) 21 CFR 211.84(d)(2)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals. - Reports of Analysis (Components) 21 CFR 211.84(d)(2)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Registered with FDA for: analysis; label; manufacture; pack.