Drug factory · FDA FEI 3015392060
Lupin Limited
Unit-2, Plot No. 6B, Sector - 17, Special Economic Zone, Mihan, Nagpur, India
Problems found, fixed voluntarily at FDA's last inspection, Sep 16, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
1 drug inspection on record since 2025: 0 with no problems, 1 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Bumetanide | Makes it and packages it | Lupin Pharmaceuticals, Inc. | 70748-323 |
| Doxycycline | Makes it and packages it | Lupin Pharmaceuticals, Inc. | 70748-338 |
| Ganirelix | Makes it and packages it | Lupin Pharmaceuticals, Inc. | 70748-274 |
| Glucagon | Makes it and packages it | Lupin Pharmaceuticals, Inc. | 70748-311 |
| Liraglutide | Makes it and packages it | Lupin Pharmaceuticals, Inc. | 70748-346 |
| Sugammadex | Makes it and packages it | Lupin Pharmaceuticals, Inc. | 70748-370, 70748-371 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Sep 16, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Sep 16, 2025 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. - Valid stability test methods 21 CFR 211.166(a)(3)
The written stability program for drug products does not include reliable, meaningful and specific test methods. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Registered with FDA for: manufacture; pack.