Drug factory · FDA FEI 1216602
Lantheus Medical Imaging, Inc.
331 Treble Cove Road, North Billerica, MA, United States
Problems found, fixed voluntarily at FDA's last inspection, Apr 9, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
9 drug inspections on record since 2009: 4 with no problems, 5 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Bicisate | Makes it, tests it, packages it and labels it | Lantheus Medical Imaging, Inc. | 11994-006 |
| Perflutren | Makes it, tests it, packages it and labels it | Lantheus Medical Imaging, Inc. | 11994-011, 11994-017 |
| Technetium Tc-99m Pertechnetate | Makes it, packages it and labels it | Lantheus Medical Imaging, Inc. | 11994-090, 11994-091 |
| Tetrakis(2-Methoxyisobutylisocyanide)copper(i) Tetrafluoroborate | Makes it, tests it, packages it and labels it | Lantheus Medical Imaging, Inc. | 11994-001, 11994-003 |
| Xenon Xe-133 | Makes it | Lantheus Medical Imaging, Inc. | 11994-127, 11994-128 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Apr 9, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 7 |
| Dec 21, 2023 | No problems found | Bioresearch Monitoring | — |
| Jan 19, 2018 | No problems found | Drug Quality Assurance | — |
| Mar 5, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Mar 5, 2015 | No problems found | Bioresearch Monitoring | 6 |
| Jun 20, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Jul 18, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | 8 |
| Jul 9, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jul 1, 2009 | No problems found | Bioresearch Monitoring | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Apr 9, 2026 inspection
- Label storage access limited to authorized personnel 21 CFR 211.122(d)
Access to the storage area for labels and labeling materials is not limited to authorized personnel. - Strict control not exercised over labeling issued 21 CFR 211.125(a)
Strict control is not exercised over labeling issued for use in drug product labeling operations. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that components and drug product containers conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. - Component written specification 21 CFR 211.84(d)(2)
Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Mar 5, 2015 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established . - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established . - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine checking of electronic equipment is not performed according to a written program designed to assure proper performance. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine checking of electronic equipment is not performed according to a written program designed to assure proper performance.
Jun 20, 2013 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Jul 18, 2011 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. - Following/documenting laboratory controls 21 CFR 211.160(a)
Established standards, sampling plans, test procedures, and laboratory control mechanisms are not followed. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Training , Education , Experience overall 21 CFR 211.25(a)
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. - Microbiological Contamination Exam 21 CFR 211.84(d)(6)
Each lot of a component that is liable to microbiological contamination that is objectionable in view of its intended use is not subjected to microbiological tests before use. - Contamination, chemical or physical change, deterioration 21 CFR 314.81(b)(1)(ii)
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Registered with FDA for: analysis; label; manufacture; pack.