Drug factory · FDA FEI 3001623073
Jubilant HollisterStier General Partnership
16751 Trans-Canada Highway, Kirkland, Canada
Serious problems, FDA action at FDA's last inspection, Nov 3, 2025.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
10 drug inspections on record since 2009: 3 with no problems, 3 with problems fixed voluntarily, 4 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Albumin Aggregated | Makes it | Jubilant DraxImage Inc., dba Jubilant Radiopharma | 65174-270 |
| Bacitracin and Neomycin and Polymyxin B | Makes it, makes the active ingredient, tests it, packages it and labels it | Rising Pharma Holdings, Inc. | 16571-754 |
| Betiatide | Makes it | Jubilant DraxImage Inc., dba Jubilant Radiopharma | 65174-261 |
| Iodine | Makes it and packages it | Guerbet LLC | 67684-1901 |
| Medronic Acid | Makes it | Jubilant DraxImage Inc., dba Jubilant Radiopharma | 65174-660 |
| Monoethanolamine | Makes it | QOL Medical, LLC. | 67871-479 |
| Pentetic Acid | Makes it, tests it and packages it | Jubilant DraxImage Inc., dba Jubilant Radiopharma | 65174-288 |
| Phenylephrine | Makes it | Bausch & Lomb Americas Inc., Paragon BioTeck, Inc. | 82260-102, 82260-103, 42702-102 +1 |
| Technetium Tc-99m Exametazime | Makes it | Jubilant DraxImage Inc., dba Jubilant Radiopharma | 65174-200 |
| Technetium Tc-99m Sestamibi | Makes it | Jubilant Draximage (USA) Inc. | 45548-141 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Nov 3, 2025 | Serious problems, FDA action | Drug Quality Assurance | 9 |
| Jun 14, 2024 | Serious problems, FDA action | Drug Quality Assurance | — |
| Feb 28, 2023 | Serious problems, FDA action | Drug Quality Assurance | 4 |
| Oct 7, 2022 | No problems found | Bioresearch Monitoring | — |
| Jun 1, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Dec 10, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 26, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Mar 26, 2012 | Serious problems, FDA action | Drug Quality Assurance | — |
| Feb 11, 2010 | No problems found | Drug Quality Assurance | — |
| Feb 5, 2009 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Nov 3, 2025 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. - Batch production and Batch Control Record Requirements 21 CFR 211.188(b)
The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing and processing. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Cleaning System 21 CFR 211.42(c)(10)(v)
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions. - Equipment to control conditions 21 CFR 211.42(c)(10)(vi)
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Feb 28, 2023 inspection
- Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Acceptance/Rejection Levels 21 CFR 211.165(d)
The statistical quality control criteria fail to include appropriate acceptance levels and rejection levels. - Comparison of Test Results to Specifications 21 CFR 211.194(a)(6)
Laboratory records are deficient in that they do not include a statement of the results of tests and how they compare to the established specifications. - Second person sign off 21 CFR 211.194(a)(8)
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy.
Jun 1, 2018 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed. - Annual visual exams of drug products 21 CFR 211.170(b)
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Sep 26, 2013 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling, and drug products conform to appropriate standards of identity, strength, quality and purity. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Protective Apparel Not Worn 21 CFR 211.28(a)
Protective apparel is not worn as necessary to protect drug products from contamination. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Registered with FDA for: analysis; label; manufacture; pack.