Drug factory · FDA FEI 3002806351
Hikma Pharmaceuticals LLC
Hikma Pharmaceuticals Saleem Bin Al Hareth Street, Building No. (21) Bayader Wadi El Seer Industrial Area P.O.Box 182400 Amman 11118 Jordan (JOR), Amman, Jordan
Problems found, fixed voluntarily at FDA's last inspection, Sep 5, 2019.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
10 drug inspections on record since 2010: 2 with no problems, 3 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Fluticasone | Makes the active ingredient | Hikma Pharmaceuticals USA Inc. | 0054-3270 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Sep 5, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 8 |
| Sep 5, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 8 |
| Jul 27, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Jul 27, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Jun 25, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Jun 25, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Apr 12, 2012 | No problems found | Drug Quality Assurance | — |
| Apr 12, 2012 | No problems found | Drug Quality Assurance | — |
| Feb 4, 2010 | No problems found | Drug Quality Assurance | — |
| Feb 4, 2010 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Sep 5, 2019 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Test methods 21 CFR 211.165(e)
The accuracy and sensitivity of test methods have not been established and documented. - Test methods 21 CFR 211.165(e)
The accuracy and sensitivity of test methods have not been established and documented. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Jul 27, 2016 inspection
- Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. - Handling and Storage to Prevent Contamination 21 CFR 211.80(b)
There was a failure to handle and store components at all times in a manner to prevent contamination. - Handling and Storage to Prevent Contamination 21 CFR 211.80(b)
There was a failure to handle and store components at all times in a manner to prevent contamination.
Jun 25, 2015 inspection
- Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. - Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established and documented.
Registered with FDA for: api manufacture.