Drug factory · FDA FEI 3003224168
Connecticut Support Services Holdings, LLC
Southington, Connecticut, United States
Matched to FDA's records by company name, because this plant's registration on the label has expired.
Problems found, fixed voluntarily at FDA's last inspection, Mar 29, 2011.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
1 drug inspection on record since 2011: 0 with no problems, 1 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Oxygen | Makes it | Connecticut Support Services Holdings, LLC | 70305-000 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Mar 29, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Mar 29, 2011 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions. - Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release. - Quality control unit review of records 21 CFR 211.192
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. - Complaint Handling Procedure 21 CFR 211.198(a)
Procedures describing the handling of written and oral complaints related to drug products are not written or followed. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.