Drug factory · FDA FEI 3004081307
Cipla Limited
L-139 to L-146, S-103 to S-105, S-107 to S-112, L-147 to L-147/1/2/3 L-147A, L-138, L-150, S-116, Verna Industrial Estate, Salcette, India
Problems found, fixed voluntarily at FDA's last inspection, Jun 21, 2024.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
12 drug inspections on record since 2009: 0 with no problems, 10 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jun 21, 2024 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Aug 26, 2022 | Serious problems, FDA action | Drug Quality Assurance | 6 |
| Sep 27, 2019 | Serious problems, FDA action | Drug Quality Assurance | 12 |
| Jan 28, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 28, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 16, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Aug 30, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Apr 17, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 30, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Nov 8, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Feb 17, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Apr 17, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jun 21, 2024 inspection
- Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Cleaning System 21 CFR 211.42(c)(10)(v)
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Aug 26, 2022 inspection
- Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Cleaning System 21 CFR 211.42(c)(10)(v)
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the to produce aseptic conditions. - Cleaning SOPs/schedules 21 CFR 211.67(b)(2)
Procedures for the cleaning and maintenance of equipment are deficient regarding maintenance and cleaning schedules, including, where appropriate, sanitizing schedules. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Sep 27, 2019 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Approval and review of procedures 21 CFR 211.100(a)
Written procedures are not reviewed and approved by the quality control unit. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process. - Sampling/testing of in-process materials 21 CFR 211.160(b)(2)
The specifications for in-process materials are deficient in that they do not include a description of the sampling plan for in-process materials. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Buildings of Suitable Size, Construction, Location 21 CFR 211.42(a)
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size and construction to facilitate cleaning, maintenance, and proper operations. - Equipment to control conditions 21 CFR 211.42(c)(10)(vi)
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions. - Equipment for Environmental Control 21 CFR 211.46(b)
Equipment for adequate control over air pressure, micro-organisms and dust is not provided when appropriate for the manufacture, processing, packing or holding of a drug product. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Written procedures not established/followed 21 CFR 211.67(b)
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Registered with FDA for: analysis; label; manufacture; pack.