Drug factory · FDA FEI 3000209735
Catalent Greenville, Inc.
1240 Sugg Parkway, Greenville, NC, United States
Problems found, fixed voluntarily at FDA's last inspection, Oct 24, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
13 drug inspections on record since 2009: 7 with no problems, 6 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Oct 24, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Jan 31, 2024 | No problems found | Drug Quality Assurance | — |
| Jul 12, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Aug 24, 2018 | No problems found | Bioresearch Monitoring | — |
| Apr 13, 2017 | No problems found | Drug Quality Assurance | — |
| Jul 14, 2016 | No problems found | Drug Quality Assurance | — |
| May 2, 2014 | No problems found | Drug Quality Assurance | — |
| Aug 21, 2013 | No problems found | Bioresearch Monitoring | — |
| May 11, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| May 11, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 18, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Oct 1, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Nov 13, 2009 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Oct 24, 2025 inspection
- Microbiological testing 21 CFR 211.165(b)
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing. - Written program not followed 21 CFR 211.166(a)
The written stability testing program is not followed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Jul 12, 2019 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
May 11, 2012 inspection
- Buildings not maintained in good state of repair 21 CFR 211.58
Buildings used in the holding of a drug product are not maintained in a good state of repair.
Registered with FDA for: analysis; label; manufacture; pack.