Drug factory · FDA FEI 3003099089
Cardinal Health 414, LLC
5601 N. Powerline Road, Ste 108, Ft. Lauderdale, FL, United States
Problems found, fixed voluntarily at FDA's last inspection, Jul 31, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
6 drug inspections on record since 2009: 1 with no problems, 5 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Flurpiridaz F-18 | Makes it | GE Healthcare Inc. | 0407-8787 |
| Flutemetamol F-18 | Makes it | Medi-Physics Inc. dba GE Healthcare. | 17156-067 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jul 31, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Oct 26, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Jun 17, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 10, 2011 | No problems found | Drug Quality Assurance | — |
| Mar 26, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 15, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jul 31, 2025 inspection
- Written QA procedures established, followed 21 CFR 212.20(e)
You did not establish and follow written quality assurance procedures. - Documentation of Non-Conforming Product Investigation 21 CFR 212.71(b)
You did not document the results of the investigation for a PET drug product that did not meet specifications. - Correction of problems 21 CFR 212.71(c)
You did not take action to correct any identified problems to prevent recurrence of a nonconforming product or other quality problem. - Lack of disinfection, equipment/supplies from lower to higher quality air FDCA 501(a)(2)(A)
Lack of disinfection of supplies at each transition from areas of lower quality air to areas of higher quality air. - Personnel, blocked or disrupted first air FDCA 501(a)(2)(A)
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
Oct 26, 2018 inspection
- Written QA procedures established, followed 21 CFR 212.20(e)
You did not establish and follow written quality assurance procedures. - Equipment procedures 21 CFR 212.30(b)
You did not implement procedures to ensure that all equipment is cleaned and properly installed, maintained, and capable of repeatedly producing valid results that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. - Conform to specs prior to release 21 CFR 212.70(c)
You did not conduct an appropriate laboratory determination to ensure that each batch of a PET drug product conforms to specifications before final release. - Documentation of Non-Conforming Product Investigation 21 CFR 212.71(b)
You did not document the results of the investigation for a PET drug product that did not meet specifications. - Correction of problems 21 CFR 212.71(c)
You did not take appropriate action to correct any identified problems to prevent recurrence of a nonconforming product or other quality problem.
Registered with FDA for: manufacture; positron emission tomography drug production.