Drug factory · FDA FEI 3012030543
Brigham and Women`s Hospital, Inc., the
75 Francis Street, Boston, MA, United States
Problems found, fixed voluntarily at FDA's last inspection, Jun 22, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
5 drug inspections on record since 2014: 1 with no problems, 2 with problems fixed voluntarily, 2 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Ammonia N-13 | Makes it | Brigham and Women's Hospital, Inc., The | 24450-113 |
| Fludeoxyglucose F-18 | Makes it | Brigham and Women's Hospital, Inc., The | 24450-647 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jun 22, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 1 |
| Apr 11, 2023 | No problems found | Drug Quality Assurance | — |
| Sep 16, 2021 | Serious problems, FDA action | Drug Quality Assurance | 5 |
| Aug 22, 2019 | Serious problems, FDA action | Drug Quality Assurance | 5 |
| Aug 15, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jun 22, 2026 inspection
- Orderly handling, prevention of mix-ups, prevention of contamination 21 CFR 212.30(a)
Your facilities are not adequate to ensure the prevention of contamination of equipment or product by substances, personnel, or environmental conditions that could reasonably be expected to have an adverse effect on product quality.
Sep 16, 2021 inspection
- Determination need for investigation 21 CFR 212.20(d)
When errors occurred or a production batch or any component of the batch, failed to meet specifications, you did not determine the need for an investigation and conduct an investigation when necessary. - Written QA procedures established, followed 21 CFR 212.20(e)
You did not follow written quality assurance procedures. - Orderly handling, prevention of mix-ups, prevention of contamination 21 CFR 212.30(a)
Your facilities are not adequate to ensure the prevention of contamination of equipment or product by substances, personnel, or environmental conditions that could reasonably be expected to have an adverse effect on product quality. - Equipment procedures 21 CFR 212.30(b)
You did not implement procedures to ensure that all equipment is cleaned, suitable for its intended purposes and properly installed, maintained, and capable of repeatedly producing valid results that could reasonably be expected to adversely affect the identity, strength, quality, or purity of a PET drug, or give erroneous or invalid test results when improperly used or maintained. - Lab sampling and test procedures 21 CFR 212.60(b)
Each laboratory did not have testing procedures which are designed to ensure that PET drug products conform to appropriate standards including established standards of identity, strength, quality and purity.
Aug 22, 2019 inspection
- Adverse effects of changes made 21 CFR 212.20(c)
You did not demonstrate that any change does not adversely affect the identity, strength, quality and purity of your PET drug. - Determination need for investigation 21 CFR 212.20(d)
When errors occurred or a production batch or any component of the batch, failed to meet specifications, you did not determine the need for an investigation, conduct an investigation and take appropriate corrective actions when necessary. - Written QA procedures established, followed 21 CFR 212.20(e)
You did not establish and follow written quality assurance procedures. - Orderly handling, prevention of mix-ups, prevention of contamination 21 CFR 212.30(a)
Your facilities are not adequate to ensure the prevention of contamination of equipment or product by substances, personnel, or environmental conditions that could reasonably be expected to have an adverse effect on product quality. - Analytical methods 21 CFR 212.60(c)
Your laboratory analytical methods are not suitable for their intended use.
Registered with FDA for: positron emission tomography drug production.