Drug factory · FDA FEI 1220785
Avista Pharma Solutions, Inc. dba Cambrex
104 Gold St, Agawam, MA, United States
Problems found, fixed voluntarily at FDA's last inspection, Jul 25, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
6 drug inspections on record since 2010: 2 with no problems, 4 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Eftrenonacog Alfa | Tests it | Bioverativ Therapeutics Inc. | 71104-911, 71104-922, 71104-933 +3 |
| Irinotecan | Tests it | Ipsen Biopharmaceuticals, Inc. | 15054-0043 |
| Thiosulfate Ion | Tests it | Fennec Pharmaceuticals Inc. | 73077-010 |
| Tocilizumab | Tests it | Biogen MA Inc. | 64406-022, 64406-023 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jul 25, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Dec 18, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Sep 5, 2018 | No problems found | Drug Quality Assurance | — |
| Jun 15, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 27, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | 8 |
| Oct 27, 2010 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jul 25, 2025 inspection
- Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Sanitation--buildings not clean, free of infestation 21 CFR 211.56(a)
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition. - Buildings not maintained in good state of repair 21 CFR 211.58
Buildings used in the processing of a drug product are not maintained in a good state of repair. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Dec 18, 2019 inspection
- Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Sep 27, 2013 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. - Lab controls established, including changes 21 CFR 211.160(a)
The establishment of standards and test procedures including any changes thereto, are not reviewed and approved by the quality control unit. - Testing and release for distribution 21 CFR 211.165(a)
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the prior to release. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Aseptic Processing Area 21 CFR 211.42(c)(10)
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Reports of Analysis (Components) 21 CFR 211.84(d)(2)
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Registered with FDA for: analysis.