Drug factory · FDA FEI 3005796917
Aurolife Pharma LLC
2400 Route 130 North, Dayton, NJ, United States
Serious problems, FDA action at FDA's last inspection, Dec 7, 2021.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
20 drug inspections on record since 2009: 4 with no problems, 5 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Dec 7, 2021 | Serious problems, FDA action | Drug Quality Assurance | 18 |
| Dec 7, 2021 | Serious problems, FDA action | Drug Quality Assurance | 18 |
| Oct 22, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Oct 22, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 14, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 14, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jul 28, 2016 | No problems found | Drug Quality Assurance | — |
| Jul 28, 2016 | No problems found | Drug Quality Assurance | — |
| Jan 12, 2016 | No problems found | Drug Quality Assurance | — |
| Jan 12, 2016 | No problems found | Drug Quality Assurance | — |
| Jul 9, 2015 | No problems found | Drug Quality Assurance | — |
| Jul 9, 2015 | No problems found | Drug Quality Assurance | — |
| Oct 15, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Oct 15, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Nov 2, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Nov 2, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 25, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| May 25, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| May 11, 2009 | No problems found | Drug Quality Assurance | — |
| May 11, 2009 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Dec 7, 2021 inspection
- Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate standards and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established. - Test methods 21 CFR 211.165(e)
The accuracy, sensitivity, specificity and reproducibility of test methods have not been established. - Review of representative number of batches 21 CFR 211.180(e)(1)
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected. - Review of representative number of batches 21 CFR 211.180(e)(1)
Written procedures are not followed for evaluations conducted at least annually to review records associated with a representative number of batches, whether approved or rejected. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Buildings not maintained in good state of repair 21 CFR 211.58
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. - Buildings not maintained in good state of repair 21 CFR 211.58
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Cleaning SOPs/instructions 21 CFR 211.67(b)(3)
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. - Cleaning SOPs/instructions 21 CFR 211.67(b)(3)
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
May 25, 2011 inspection
- Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other drug products that may have been associated with the specific failure or discrepancy. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Registered with FDA for: analysis; label; manufacture; pack; relabel; repack.