Drug factory · FDA FEI 2528933
ARx, LLC
400 Seaks Run Road, Glen Rock, PA, United States
Problems found, fixed voluntarily at FDA's last inspection, Jun 10, 2026.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
9 drug inspections on record since 2009: 4 with no problems, 5 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Dexmedetomidine | Makes it | BioXcel Therapeutics, Inc. | 81092-1120, 81092-1180 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Jun 10, 2026 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Jun 3, 2022 | Problems found, fixed voluntarily | Drug Quality Assurance | 7 |
| Aug 20, 2021 | No problems found | Drug Quality Assurance | — |
| Mar 29, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Aug 18, 2016 | No problems found | Drug Quality Assurance | — |
| Feb 18, 2014 | No problems found | Drug Quality Assurance | — |
| Jul 29, 2011 | No problems found | Drug Quality Assurance | — |
| Dec 3, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 14, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Jun 10, 2026 inspection
- Records reviewed annually 21 CFR 211.180(e)
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Quality control unit review of records 21 CFR 211.192
Drug product production and control records, are not by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Jun 3, 2022 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Identification of persons involved, each significant step 21 CFR 211.188(b)(11)
Batch production and control records do not include the identification of the persons performing and checking each significant step in the operation, for each batch of drug product produced. - Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of an unexplained discrepancy did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Equipment for Environmental Control 21 CFR 211.46(b)
Equipment for adequate control over air pressure, micro-organisms and dust is not provided when appropriate for the manufacture, processing, packing or holding of a drug product. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Registered with FDA for: manufacture; pack.