Drug factory · FDA FEI 2410375
American Regent, Inc.
5 Ramsey Road, Shirley, NY, United States
Problems found, fixed voluntarily at FDA's last inspection, Apr 24, 2024.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
12 drug inspections on record since 2008: 1 with no problems, 10 with problems fixed voluntarily, 1 with FDA action.
What it does, for whom
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Apr 24, 2024 | Problems found, fixed voluntarily | Drug Quality Assurance | 7 |
| Nov 15, 2019 | No problems found | Drug Quality Assurance | — |
| Apr 11, 2018 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Feb 28, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Feb 26, 2016 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Oct 29, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | 5 |
| Mar 29, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Mar 15, 2011 | Serious problems, FDA action | Drug Quality Assurance | 18 |
| Oct 29, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | 3 |
| Nov 5, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | 2 |
| Dec 16, 2008 | Problems found, fixed voluntarily | Postmarket Surv. and Epidemiology | 14 |
| Dec 16, 2008 | Problems found, fixed voluntarily | Drug Quality Assurance | 14 |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Apr 24, 2024 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Storage under appropriate conditions 21 CFR 211.142(b)
Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected. - Air Supply 21 CFR 211.42(c)(10)(iii)
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. - Computer control of master formula records 21 CFR 211.68(b)
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Apr 11, 2018 inspection
- Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in the particular operations they perform as part of their function.
Feb 26, 2016 inspection
- Electronic records 21 CFR 11
Electronic records are used, but they do not meet audit trail requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records. - Written record of complaint to include findings, follow-up 21 CFR 211.198(b)(2)
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up .
Oct 29, 2014 inspection
- Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Procedures for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Registered with FDA for: analysis; label; manufacture; pack.