Problems found, fixed voluntarily at FDA's last inspection, Nov 7, 2025.
Voluntary Action Indicated: inspectors found problems, but not serious enough for FDA to take action. The company is expected to fix them.
12 drug inspections on record since 2009: 1 with no problems, 11 with problems fixed voluntarily, 0 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Benoxinate and Fluorescein | Makes it | Bausch & Lomb Americas Inc., Bausch & Lomb Incorporated | 82260-734, 24208-734 |
| Bicarbonate Ion | Makes it | Onpharma, Inc. | 50509-100 |
| Naloxone | Makes it | Uswm, LLC | 78670-140 |
| Perfluorohexyloctane | Makes it | Bausch & Lomb Incorporated | 24208-377 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| Nov 7, 2025 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| May 21, 2021 | Problems found, fixed voluntarily | Drug Quality Assurance | 4 |
| Feb 14, 2019 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 26, 2017 | Problems found, fixed voluntarily | Unapproved and Misbranded Drugs | — |
| May 26, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Aug 21, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jul 25, 2014 | No problems found | Drug Quality Assurance | — |
| Aug 16, 2013 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Apr 16, 2012 | Problems found, fixed voluntarily | Drug Quality Assurance | 6 |
| Mar 23, 2011 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Sep 3, 2010 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| May 5, 2009 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
Nov 7, 2025 inspection
- Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Extent of discrepancy, failure investigations 21 CFR 211.192
Investigations of an unexplained discrepancy did not extend to other drug products that may have been associated with the specific failure or discrepancy. - Cleaning System 21 CFR 211.42(c)(10)(v)
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
May 21, 2021 inspection
- Investigations of discrepancies, failures 21 CFR 211.192
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Environmental Monitoring System 21 CFR 211.42(c)(10)(iv)
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. - Written calibration / inspection records not kept 21 CFR 211.68(a)
Records of the inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Apr 16, 2012 inspection
- SOPs not followed / documented 21 CFR 211.100(b)
Written production and process control procedures are not followed in the execution of production and process control functions and documented at the time of performance. - Control procedures to monitor and validate performance 21 CFR 211.110(a)
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product. - Validation lacking for sterile drug products 21 CFR 211.113(b)
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. - Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product. - Air Supply 21 CFR 211.42(c)(10)(iii)
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration, inspection, and checking of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Registered with FDA for: analysis; label; manufacture; pack.