Drug factory · FDA FEI 3004723334
Acino Products, LLC.
Hamilton, New Jersey, United States
Matched to FDA's records by company name, because this plant's registration on the label has expired.
Serious problems, FDA action at FDA's last inspection, May 21, 2025.
Official Action Indicated: inspectors found significant problems and FDA recommended regulatory action, such as a warning letter or import alert.
12 drug inspections on record since 2013: 2 with no problems, 3 with problems fixed voluntarily, 7 with FDA action.
What it does, for whom
| Drug | Role | For | NDC |
|---|---|---|---|
| Hydrocortisone | Makes it | Acino Products, LLC. | 68784-108 |
FDA inspection history
| Ended | Result | Program | Problems noted |
|---|---|---|---|
| May 21, 2025 | Serious problems, FDA action | Drug Quality Assurance | 3 |
| Aug 30, 2024 | Serious problems, FDA action | Drug Quality Assurance | 10 |
| Nov 14, 2017 | Problems found, fixed voluntarily | Drug Quality Assurance | 7 |
| Nov 22, 2016 | No problems found | Drug Quality Assurance | — |
| Oct 26, 2015 | Serious problems, FDA action | Unapproved and Misbranded Drugs | 12 |
| Oct 26, 2015 | Problems found, fixed voluntarily | Drug Quality Assurance | 12 |
| Jan 21, 2015 | Serious problems, FDA action | Unapproved and Misbranded Drugs | — |
| Aug 19, 2014 | Serious problems, FDA action | Unapproved and Misbranded Drugs | 10 |
| Aug 19, 2014 | Serious problems, FDA action | Drug Quality Assurance | 10 |
| Mar 5, 2014 | Serious problems, FDA action | Unapproved and Misbranded Drugs | — |
| Mar 5, 2014 | Problems found, fixed voluntarily | Drug Quality Assurance | — |
| Jun 13, 2013 | No problems found | Drug Quality Assurance | — |
What inspectors wrote down
From FDA's Form 483 citations: conditions an investigator observed that may violate drug manufacturing rules, as FDA published them.
May 21, 2025 inspection
- Adequate number of batches on stability 21 CFR 211.166(b)
An adequate number of batches of each drug product are not tested nor are records of such data maintained to determine an appropriate expiration date. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Equipment for Environmental Control 21 CFR 211.46(b)
Equipment for adequate control over humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Aug 30, 2024 inspection
- Absence of Written Procedures 21 CFR 211.100(a)
Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess. - Procedures for non-sterile drug products 21 CFR 211.113(a)
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established. - Lack of written stability program 21 CFR 211.166(a)
There is no written testing program designed to assess the stability characteristics of drug products. - Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product. - Contract drug products--lack of responsibility 21 CFR 211.22(a)
The quality control unit lacks responsibility for approving or rejecting drug products manufactured and packed under contract by another company. - Procedures not in writing, fully followed 21 CFR 211.22(d)
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed. - Equipment for Environmental Control 21 CFR 211.46(b)
Equipment for adequate control over temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product. - Sanitation--buildings not clean, free of infestation 21 CFR 211.56(a)
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition. - Cleaning SOPs/instructions 21 CFR 211.67(b)(3)
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. - Identity Testing of Each Component 21 CFR 211.84(d)(1)
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Nov 14, 2017 inspection
- Deviations from laboratory control requirements 21 CFR 211.160(a)
Deviations from written laboratory mechanisms are not recorded and justified. - Scientifically sound laboratory controls 21 CFR 211.160(b)
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity. - Calibration - at intervals, written program, remedial action 21 CFR 211.160(b)(4)
The calibration of instruments, apparatus, gauges and recording devices is not done at suitable intervals in accordance with an established written program. - Statement of methods and data 21 CFR 211.194(a)(2)
Laboratory records do not include a statement of each method used in the testing of a sample. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance. - Cleaning / Sanitizing / Maintenance 21 CFR 211.67(a)
Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product. - Calibration/Inspection/Checking not done 21 CFR 211.68(a)
Routine calibration of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
Oct 26, 2015 inspection
- Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product. - Items to cover on annual reviews 21 CFR 211.180(e)(2)
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product. - Lack of quality control unit 21 CFR 211.22(a)
There is no quality control unit. - Lack of quality control unit 21 CFR 211.22(a)
There is no quality control unit. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations. - Training--operations, GMPs, written procedures 21 CFR 211.25(a)
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. - Equipment Design, Size and Location 21 CFR 211.63
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use. - Equipment construction - reactive surfaces 21 CFR 211.65(a)
Equipment surfaces that contact in-process materials and drug products are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements. - Equipment construction - reactive surfaces 21 CFR 211.65(a)
Equipment surfaces that contact in-process materials and drug products are reactive, additive or absorptive so as to alter the safety, identity, strength, quality, or purity of the drug product beyond the official or other established requirements. - Cleaning SOPs/instructions 21 CFR 211.67(b)(3)
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance. - Cleaning SOPs/instructions 21 CFR 211.67(b)(3)
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.